Calculation of parameters of technological equipment used in the hydrodynamic method of cleaning the drainage
Национальная академия наук Беларуси

РУП "НПЦ НАН Беларуси по земледелию"

Республиканское научное дочернее унитарное предприятие
Author: N. N. Pogodin, A. S. Anzhenkov, V. A. Bolbyshko
Article code: UDC 631.3:626:86

Keywords: drainage flushing, flushing pipe, pressure loss, flow rate, speed, diameter, pressure

// Мелиорация.– 2020. – №2(92) – P 5–11

Calculations are presented to determine the pressure loss in the water supply elements of the installation for washing the drainage, taking into account the used water flow rate, the inner diameter of the washing pipe and its length. Based on the calculations, it is recommended that the installation for washing the drainage UPD-120 be completed with a flushing pipe with an inner diameter of 20 mm and a length of 300 m.