Keywords: electroactivator of water, electroactivation of water solutions, anolyte, catholyte, equivalent circuit, chamber, diaphragm, resistance, resistivity, power, water, temperature
// Мелиорация.– 2022. – №2(100) – P 20–23
The effect of an electroactivator whose interelectrode space is separated by a diaphragm has been analyzed. The dependence of the resistance in the chambers at different water temperatures has been established. The comparison of experimental and theoretical values of resistances is given.