Keywords: siphon catchment, vertical drainage, submersible pump, vacuum pump, dynamic level, flow rate
of wells
// Мелиорация.– 2021. – №3(97) – P 43–49
The article presents the results of research on one of the effective design solutions for vertical drainage with siphon catchments. The conditions of their application are given, the design of various types of siphons and used drainage wells is given. Operation modes of siphon catchments, possible volumes of water pumping from wells and their radii of influence on groundwater levels are established. An economic estimate of the cost of their construction and operation was given.